Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage
Electric Cooling & 3 Stage Gas Heating, Heat Pump, Electric or Hydronic Heat.
Digital
Thermostat
Digital
Thermostat
residential
T1
700
HEAT
COOL
HEAT
PUMP
PROGRAMMABLE
1-DAY
PROGRAMMABLE
1-DAY
up to
& 1-cool
up to
& 1-cool
2-heat
2-heat
THERMOSTAT
CONFIGURABLE IN SETUP:
Auto or Manual changeover
Programmable or
Non-Programmable
Control up to 2 Heat &
1 Cool Stages
Backlit Display & Button
Legends
Aux Heat Indicator
Outdoor Sensor Ready
Accepts EZ Programmer
Accepts Optional IR
Remote Control
Accepts Comfort Call
Phone Control Accessory
INSTALLATION
INSTRUCTIONS
INSTALLATION
INSTRUCTIONS
Vista de página 0
1 2 3 4 5 6 ... 16 17

Resumo do Conteúdo

Página 1 - INSTRUCTIONS

Venstar Inc. 08/07Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & 3 Stage Gas He

Página 2 - Tested to Comply

HPGASBOELECGAS(FAN)W1Y1GRCW2RS2RSGNDRS+5Y1GRCW1/O/BRS+5RSGNDW26 Conductor 18 gauge unshielded cable from the thermostat to the equipment.24 vac return

Página 3

HPGASBOELECGAS(FAN)W1Y1GRCW2RS2RSGNDRS+5Y1GRCW1/O/BRS+5RSGNDW26 Conductor 18 gauge unshielded cable from the thermostat to the equipment.24 vac return

Página 4 - Table of Contents

HPGASBOELECGAS(FAN)W1Y1GRCW2RS2RSGNDRS+5Y1GRCW1/O/BRS+5RSGNDW26 Conductor 18 gauge unshielded cable from the thermostat to the equipment.24 vac return

Página 5 - Preparation

Page 4.64Installing the Outdoor SensorSee the Outdoor Sensor accessory for further details.The Outdoor Sensor measures outdoor air temperature and sen

Página 6 - SECTION 2

Press the MODE button repeatedly until the COOL icon appears on the display. or Down buttons until the set temperature is 10 degrees below room tempe

Página 7 - Wire Connections

Page 6.1SECTION 6Calibrating the Thermostat SensorsAfter calibration is complete, press the MODE button once to return to normal operation.Under norma

Página 8 - Section 4 Contents:

Page 7.1SECTION 7TroubleShooting7SYMPTOM: The air conditioning does not attempt to turn on.CAUSE: The compressor timer lockout may prevent t

Página 9 - Page 4.2

SYMPTOM: When controlling a residential heat pump, and asking for cooling, the heat comes on.CAUSE: The thermostat reversing valve jumper is

Página 10 - Page 4.3

Page iThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not ca

Página 12 - Page 4.5

2136745PreparationRemove & Replace the Old ThermostatSample WiringDiagramsCalibrating the Thermostat SensorsTest OperationTroubleShootingPage iii

Página 13 - Page 4.6

Page 1.1SECTION 1Preparation1Assemble tools Flat BladeScrewdriverWire cutter& StripperMake sure your Heater/Air Conditioner is working properly be

Página 14 - Test Operation

Page 2.1SECTION 2Remove & Replace the Old Thermostat2Remove the cover of the old thermostat.If it does not come off easily check for screws.Loosen

Página 15 - SECTION 6

Page 3.1SECTION 3Wire ConnectionsIf the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart belo

Página 16 - TroubleShooting

Page 4.1Section 4 Contents: HVAC Equipment Wiring...4.2 Installing the Outdoor Sensor...4.6 SECTION 4Sample Wiring Diagrams4

Página 17

Y1GRCW1/O/BRS+5RSGNDW26 Conductor 18 gauge unshielded cable from the thermostat to the equipment.24 vac return fan relaycompressor relay1st stage heat