Venstar ACC0431 Especificações Página 31

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 37
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 30
2
Wire
Contact
Base
Wire
Stop
Blue
Tap
Wire
Plastic
Flange
A07934
LPS
Run
Wire
Yellow w/ Red
Blue Tap
Wire
A07944
Fig. 1 -- Installation
(Y) (C)
T1 T2
C
T3
LPS
24 VAC24 VAC
LPS = Low Pressure Switch
C = Contactor Coil
T1 = 24 VAC Input
T2 = Switch Override
T3 = 24 VAC Com
TDR = Time Delay Relay
Circuit Board
A07933
Fig. 2 -- Wiring for Winter Start Control
Run Wire
yellow w/red stripe
LPS
Switch at
Outdoor Unit
Insulated Tap Connector
Blue
(tap wire)
Brown
Yellow
CRY
TDR
ODU
TSTAT Field
Connections
LPS
Connector
at Circuit Board
12 3
R
C
Y
LS
HK38EA004
(Control Board)
T1
T3 T2
A07932
Fig. 3 -- Infinity/Evolutio n (HK38EA004)
LPS Run--Wire is Connected to pin #1
Run Wire
yellow w/red stripe
LPS
Switch at
Outdoor Unit
Insulated Tap Connector
Blue
(tap wire)
Brown
Yellow
CY
TDR
ODU
TSTAT Field
Connections
LPS
Connector
at Circuit Board
123
T1
T3 T2
A07931
Fig. 4 -- TechAssist (HK35AC005)
LPS Run--Wire is Connected to pin #2
Copyright 2008 CAC / BDP D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/08
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
C a t a l o g N o : I I K --- K A A W S --- 0 4
R e p l a c e s : A G --- A A W S --- 0 3
Vista de página 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 37

Comentários a estes Manuais

Sem comentários